Battery FirebreakBattery fire-safety reference

Materials data

Thermal-runaway barrier materials compared

Fibre-reinforced silica aerogel gives the lowest thermal conductivity of the common barrier materials. Mica resists flame, particle jets and high voltage best but insulates poorly. Ceramic-fibre paper sits between the two. Most production cell-to-cell barriers are now laminates that combine these properties.

Updated 59 values checked against original datasheetsJSONMethodology

Every value carries a status. Verified means it was read in the cited datasheet, with page and test condition recorded. Typical means a range compiled from several documents and not yet traced line by line. Use the supplier's current datasheet for design.

Typical thermal conductivity ranges by material at room and elevated temperature, logarithmic scale0.010.030.10.31310AerogelMicaCeramic fibreIntumescent / endothermicSilicone foamPhase-change (PCM)Composite laminate
About 25 °CAbout 400–600 °C (where meaningful)Thermal conductivity, W/(m·K), log scale
Figure 1. Typical thermal conductivity ranges. Intumescent, silicone-foam and phase-change materials expand, decompose or melt rather than holding a fixed conductivity, so they have no elevated-temperature bar.

Summary of typical properties

Materialk at ~25 °C, W/(m·K)k at elevated temperatureTemperature limitDensityTypical thicknessCompressionElectrical insulation
Silica aerogel blanket / pad (fibre-reinforced)0.015–0.025≈0.035–0.05 at 400 °C; ≈0.05–0.09 at 500–600 °C≈650 °C continuous (unshielded); short exposures higher when faced≈70–300 kg/m³1–5 mm (often 2–3 mm)Compressible ≈10–30 %, partial reboundInsulating; breakdown typically ≥3.5 kV per pad when encapsulated
Mica sheet / board (muscovite, phlogopite)≈0.2–0.6 (through-plane)Stays ≈0.2–0.6Muscovite ≈500–600 °C; phlogopite ≈700–800 °C continuous; higher short-term≈1,800–2,350 kg/m³ (bonded sheet)0.2–2 mmEssentially rigidExcellent; typically ≥20 kV/mm at room temperature
Ceramic-fibre / bio-soluble fibre paper≈0.035–0.05≈0.06–0.12 at 400 °C; ≈0.08–0.16 at 600 °CFibre rated ≈1,100–1,400 °C≈140–290 kg/m³0.8–6 mmSome initial compression; limited reboundGood when dry; binder burns out at ≈250–450 °C
Intumescent / endothermic barrier sheet≈0.05–0.3 (before activation)Not comparable: works by expanding or absorbing heatActivates ≈150–200 °C; char stable to ≈1,000 °C≈300–1,500 kg/m³0.5–3 mm between cellsVaries; expansion is irreversibleDepends on formulation: graphite-based chars become conductive
Silicone foam / compression pad≈0.06–0.15Polymer pyrolyses above ≈350 °C; ceramifying grades form a silica char≈200 °C continuous; fire-blocking grades survive short flame exposure≈190–800 kg/m³1.5–6 mmBest reversible compression and low compression setGood
Phase-change material (PCM) plate≈0.2 (paraffin) to 3–15 (graphite composite)Not applicable: decomposes above ≈200–300 °CMelts at ≈25–70 °C; organic types unstable above ≈200 °C≈760–1,700 kg/m³2–6 mmRigidParaffin insulates; graphite composites conduct
Composite barrier (aerogel or fibre core + mica / film facing)≈0.015–0.03 (aerogel core)≈0.04–0.06 at 500 °C (aerogel core); higher for fibre coreFacing survives short exposures ≈1,000 °C+≈150–300 kg/m³0.5–6 mm (often 1–3 mm)Core compresses ≈10–30 %Set by the mica or polymer facing

Table 1. Typical ranges by class. Verified values for named products are listed in each section below.

1. Silica aerogel blanket / pad (fibre-reinforced)

Insulating core

Silica aerogel trapped in a glass- or ceramic-fibre mat. Its nanoporous structure suppresses gas conduction, giving the lowest thermal conductivity of the common barrier materials at room temperature and a clear advantage at a few hundred °C. Most battery grades are encapsulated in a film or faced with mica to control dust and add electrical and abrasion resistance.

k at ~25 °C, W/(m·K)
0.015–0.025 Typical
k at elevated temperature
≈0.035–0.05 at 400 °C; ≈0.05–0.09 at 500–600 °C Typical
Temperature limit
≈650 °C continuous (unshielded); short exposures higher when faced Typical
Density
≈70–300 kg/m³ Typical
Typical thickness
1–5 mm (often 2–3 mm) Typical
Compression
Compressible ≈10–30 %, partial rebound Typical
Electrical insulation
Insulating; breakdown typically ≥3.5 kV per pad when encapsulated Typical

Strengths

  • Lowest thermal conductivity of common barrier materials, so thin layers are effective
  • Light and compressible, so it can double as a compression pad between prismatic or pouch cells
  • Widely qualified in production EV packs

Limitations

  • The silica network can sinter and lose its low conductivity above roughly 650–800 °C if not shielded
  • Unencapsulated material sheds dust
  • More expensive per square metre than mica or ceramic-fibre paper

Commercial examples

Listed for reference. Not an endorsement and not paid for.

2. Mica sheet / board (muscovite, phlogopite)

Flame & voltage shield

Mica paper bonded with silicone resin into flexible sheet or rigid board. It insulates heat about ten times worse than aerogel but is very hard to burn through, resists the abrasive jet of hot particles from a venting cell, and keeps high dielectric strength at temperature. It is the standard material for pack lids, busbar shields and the facing layer of composite barriers.

k at ~25 °C, W/(m·K)
≈0.2–0.6 (through-plane) Typical
k at elevated temperature
Stays ≈0.2–0.6 Typical
Temperature limit
Muscovite ≈500–600 °C; phlogopite ≈700–800 °C continuous; higher short-term Typical
Density
≈1,800–2,350 kg/m³ (bonded sheet) Typical
Typical thickness
0.2–2 mm Typical
Compression
Essentially rigid Typical
Electrical insulation
Excellent; typically ≥20 kV/mm at room temperature Typical

Strengths

  • Very high dielectric strength, retained at elevated temperature
  • Resists flame burn-through and particle erosion
  • Low cost and mature supply chain

Limitations

  • High density and much higher thermal conductivity than aerogel
  • Rigid: cannot absorb cell swelling on its own

Verified product values

ProductPropertyValueConditionSource
Pamitherm 41130 (phlogopite mica paper, silicone resin)
Von Roll, via VRI Composites
k at ~25 °C, W/(m·K)0.18 W/(m·K)temperature not stated[2], properties table
Pamitherm 41130 (phlogopite mica paper, silicone resin)
Von Roll, via VRI Composites
Temperature limit1000 °C'max. heat resistance' as stated by the supplier[2], properties table

Commercial examples

Listed for reference. Not an endorsement and not paid for.

3. Ceramic-fibre / bio-soluble fibre paper

High-temperature insulation

Paper made from alumina-silica refractory fibres or alkaline-earth silicate (bio-soluble) fibres with a small organic binder. It survives far higher temperatures than aerogel at low cost, but insulates less well at the temperatures that matter for propagation.

k at ~25 °C, W/(m·K)
≈0.035–0.05 Typical
k at elevated temperature
≈0.06–0.12 at 400 °C; ≈0.08–0.16 at 600 °C Typical
Temperature limit
Fibre rated ≈1,100–1,400 °C Typical
Density
≈140–290 kg/m³ Typical
Typical thickness
0.8–6 mm Typical
Compression
Some initial compression; limited rebound Typical
Electrical insulation
Good when dry; binder burns out at ≈250–450 °C Typical

Strengths

  • Very high temperature resistance
  • Low cost and light weight
  • Easy to die-cut and laminate with mica

Limitations

  • Higher conductivity than aerogel at 400–600 °C
  • Organic binder burns off on first heating, releasing smoke
  • Refractory ceramic fibre (RCF) has health classifications in some markets; bio-soluble grades avoid this

Verified product values

ProductPropertyValueConditionSource
3M Thermal Runaway Barrier 600/700
3M
k at ~25 °C, W/(m·K)< 0.045 W/(m·K)25 °C, mat only (non-classified inorganic fibre mat)[3], Highlights
3M Thermal Runaway Barrier 600/700
3M
Temperature limit1200 °Cbase mat high-temperature stability[3], Highlights
Superwool EST E Paper
Morgan Advanced Materials
k at elevated temperature0.06 W/(m·K)200 °C; thickness-dependent where stated[5], p. 2
Superwool EST E Paper
Morgan Advanced Materials
k at elevated temperature0.09 W/(m·K)400 °C; thickness-dependent where stated[5], p. 2
Superwool EST E Paper
Morgan Advanced Materials
k at elevated temperature0.13 W/(m·K)600 °C; thickness-dependent where stated[5], p. 2
Superwool EST E Paper
Morgan Advanced Materials
k at elevated temperature0.16 W/(m·K)800 °C; thickness-dependent where stated[5], p. 2
Superwool EST E Paper
Morgan Advanced Materials
k at elevated temperature0.20 W/(m·K)1000 °C; thickness-dependent where stated[5], p. 2
Superwool EST E Paper
Morgan Advanced Materials
Density450 kg/m³as supplied[5], p. 2
Superwool EST E Paper
Morgan Advanced Materials
Typical thickness0.8–6 mmavailable range[5], p. 2
Superwool EST E Paper
Morgan Advanced Materials
Electrical insulation>2 (dielectric breakdown; unit printed as 'kΩ, kV/mm') as stated[5], p. 2
Superwool EST E Paper
Morgan Advanced Materials
Temperature limit1100–1300 °Cclassification temperature[5], p. 2
Superwool EST G Paper
Morgan Advanced Materials
k at elevated temperature0.05 W/(m·K)200 °C; thickness-dependent where stated[6], p. 2
Superwool EST G Paper
Morgan Advanced Materials
k at elevated temperature0.07 W/(m·K)400 °C; thickness-dependent where stated[6], p. 2
Superwool EST G Paper
Morgan Advanced Materials
k at elevated temperature0.11 W/(m·K)600 °C; thickness-dependent where stated[6], p. 2
Superwool EST G Paper
Morgan Advanced Materials
k at elevated temperature0.16 W/(m·K)800 °C; thickness-dependent where stated[6], p. 2
Superwool EST G Paper
Morgan Advanced Materials
k at elevated temperature0.23 W/(m·K)1000 °C; thickness-dependent where stated[6], p. 2
Superwool EST G Paper
Morgan Advanced Materials
Density240–300 kg/m³as supplied[6], p. 2
Superwool EST G Paper
Morgan Advanced Materials
Typical thickness1–6 mmavailable range[6], p. 2
Superwool EST G Paper
Morgan Advanced Materials
Electrical insulation>2 (dielectric breakdown; unit printed as 'kΩ, kV/mm') as stated[6], p. 2
Superwool EST G Paper
Morgan Advanced Materials
Temperature limit1100–1300 °Cclassification temperature[6], p. 2
Superwool EST P Paper
Morgan Advanced Materials
k at elevated temperature0.05 W/(m·K)200 °C; thickness-dependent where stated[7], p. 2
Superwool EST P Paper
Morgan Advanced Materials
k at elevated temperature0.07 W/(m·K)400 °C; thickness-dependent where stated[7], p. 2
Superwool EST P Paper
Morgan Advanced Materials
k at elevated temperature0.11 W/(m·K)600 °C; thickness-dependent where stated[7], p. 2
Superwool EST P Paper
Morgan Advanced Materials
k at elevated temperature0.16 W/(m·K)800 °C; thickness-dependent where stated[7], p. 2
Superwool EST P Paper
Morgan Advanced Materials
k at elevated temperature0.23 W/(m·K)1000 °C; thickness-dependent where stated[7], p. 2
Superwool EST P Paper
Morgan Advanced Materials
Density272–352 kg/m³as supplied[7], p. 2
Superwool EST P Paper
Morgan Advanced Materials
Typical thickness1–6 mmavailable range[7], p. 2
Superwool EST P Paper
Morgan Advanced Materials
Electrical insulation>3 (dielectric breakdown; unit printed as 'kΩ, kV/mm') as stated[7], p. 2
Superwool EST P Paper
Morgan Advanced Materials
Temperature limit1100–1300 °Cclassification temperature[7], p. 2
Superwool EST C30 compression paper
Morgan Advanced Materials
k at elevated temperature0.06 W/(m·K)200 °C, ASTM C201 / ASTM C177 as printed in the table header; thickness-dependent where stated[9], p. 2
Superwool EST C30 compression paper
Morgan Advanced Materials
k at elevated temperature0.08 W/(m·K)400 °C, ASTM C201 / ASTM C177 as printed in the table header; thickness-dependent where stated[9], p. 2
Superwool EST C30 compression paper
Morgan Advanced Materials
k at elevated temperature0.11 W/(m·K)600 °C, ASTM C201 / ASTM C177 as printed in the table header; thickness-dependent where stated[9], p. 2
Superwool EST C30 compression paper
Morgan Advanced Materials
k at elevated temperature0.15 W/(m·K)800 °C, ASTM C201 / ASTM C177 as printed in the table header; thickness-dependent where stated[9], p. 2
Superwool EST C30 compression paper
Morgan Advanced Materials
Density240–310 kg/m³as supplied[9], p. 2
Superwool EST C30 compression paper
Morgan Advanced Materials
Compression25–35 / 380–470 kPacompression resistance at 20 % / 60 % deflection[9], p. 2
Superwool EST C310 compression paper
Morgan Advanced Materials
k at elevated temperature0.06 W/(m·K)200 °C, ASTM C201 / ASTM C177 as printed in the table header; thickness-dependent where stated[9], p. 2
Superwool EST C310 compression paper
Morgan Advanced Materials
k at elevated temperature0.08 W/(m·K)400 °C, ASTM C201 / ASTM C177 as printed in the table header; thickness-dependent where stated[9], p. 2
Superwool EST C310 compression paper
Morgan Advanced Materials
k at elevated temperature0.10 W/(m·K)600 °C, ASTM C201 / ASTM C177 as printed in the table header; thickness-dependent where stated[9], p. 2
Superwool EST C310 compression paper
Morgan Advanced Materials
k at elevated temperature0.13 W/(m·K)800 °C, ASTM C201 / ASTM C177 as printed in the table header; thickness-dependent where stated[9], p. 2
Superwool EST C310 compression paper
Morgan Advanced Materials
Density400–510 kg/m³as supplied[9], p. 2
Superwool EST C310 compression paper
Morgan Advanced Materials
Compression295–340 / 1700–1970 kPacompression resistance at 20 % / 60 % deflection[9], p. 2

Commercial examples

Listed for reference. Not an endorsement and not paid for.

4. Intumescent / endothermic barrier sheet

Active, expands in fire

Active materials. Intumescent sheets swell into an insulating char when heated, filling gaps and adding thickness. Endothermic sheets absorb heat by releasing chemically bound water. Both buy time rather than offering a fixed thermal resistance.

k at ~25 °C, W/(m·K)
≈0.05–0.3 (before activation) Typical
k at elevated temperature
Not comparable: works by expanding or absorbing heat Typical
Temperature limit
Activates ≈150–200 °C; char stable to ≈1,000 °C Typical
Density
≈300–1,500 kg/m³ Typical
Typical thickness
0.5–3 mm between cells Typical
Compression
Varies; expansion is irreversible Typical
Electrical insulation
Depends on formulation: graphite-based chars become conductive Typical

Strengths

  • Thin when cold; insulation increases in a fire
  • Endothermic types delay temperature rise of the protected cell
  • Expansion seals gaps against hot gas

Limitations

  • Single use: the reaction is irreversible
  • Expandable-graphite chars conduct electricity unless laminated with a dielectric
  • Expansion force can load the neighbouring cells

5. Silicone foam / compression pad

Compression & sealing

Closed-cell or syntactic silicone foams used mainly to manage cell swelling and hold stack pressure. Fire-rated and ceramifying grades add some thermal-runaway protection, often in combination with a mica or aerogel layer.

k at ~25 °C, W/(m·K)
≈0.06–0.15 Typical
k at elevated temperature
Polymer pyrolyses above ≈350 °C; ceramifying grades form a silica char Typical
Temperature limit
≈200 °C continuous; fire-blocking grades survive short flame exposure Typical
Density
≈190–800 kg/m³ Typical
Typical thickness
1.5–6 mm Typical
Compression
Best reversible compression and low compression set Typical
Electrical insulation
Good Typical

Strengths

  • Excellent long-term compression behaviour for cell breathing
  • Seals and gaskets well
  • UL 94 V-0 grades are common

Limitations

  • Higher conductivity than aerogel
  • Continuous service limited to about 200 °C
  • Releases volatiles when it decomposes

Commercial examples

Listed for reference. Not an endorsement and not paid for.

6. Phase-change material (PCM) plate

Thermal buffer (not a fire barrier)

Plates that absorb heat while melting, used to smooth temperature peaks in normal operation. They are not fire barriers: organic PCMs are flammable and graphite-filled composites conduct heat toward neighbouring cells once the latent heat is used up.

k at ~25 °C, W/(m·K)
≈0.2 (paraffin) to 3–15 (graphite composite) Typical
k at elevated temperature
Not applicable: decomposes above ≈200–300 °C Typical
Temperature limit
Melts at ≈25–70 °C; organic types unstable above ≈200 °C Typical
Density
≈760–1,700 kg/m³ Typical
Typical thickness
2–6 mm Typical
Compression
Rigid Typical
Electrical insulation
Paraffin insulates; graphite composites conduct Typical

Strengths

  • Large latent heat buffers short temperature spikes
  • Can reduce cooling-system demand

Limitations

  • No protection once melted
  • Organic PCMs add fuel in a fire
  • Graphite composites conduct heat and electricity

Verified product values

ProductPropertyValueConditionSource
Rubitherm RT35HC
Rubitherm Technologies
k at ~25 °C, W/(m·K)0.2 W/(m·K)both phases (solid and liquid)[1], p. 1
Rubitherm RT35HC
Rubitherm Technologies
Density0.83 kg/Lsolid, 20 °C (0.77 kg/L liquid, 40 °C)[1], p. 1
Rubitherm RT35HC
Rubitherm Technologies
Temperature limit70 °Cmax. operation temperature; melting range 34–36 °C; flash point 177 °C[1], p. 1

Commercial examples

  • RT35HC, Rubitherm Technologies, Germany

Listed for reference. Not an endorsement and not paid for.

7. Composite barrier (aerogel or fibre core + mica / film facing)

All-round production barrier

Laminates that put a low-conductivity core (aerogel or fibre) between tougher facings (mica, ceramic paper, polyimide or PET film). This is the dominant format in current production because it covers all four barrier jobs: insulation, compliance, dielectric strength and burn-through resistance.

k at ~25 °C, W/(m·K)
≈0.015–0.03 (aerogel core) Typical
k at elevated temperature
≈0.04–0.06 at 500 °C (aerogel core); higher for fibre core Typical
Temperature limit
Facing survives short exposures ≈1,000 °C+ Typical
Density
≈150–300 kg/m³ Typical
Typical thickness
0.5–6 mm (often 1–3 mm) Typical
Compression
Core compresses ≈10–30 % Typical
Electrical insulation
Set by the mica or polymer facing Typical

Strengths

  • Balances insulation, compression, dielectric and burn-through performance
  • Dust-free when fully encapsulated

Limitations

  • Higher cost than single materials
  • Thicker and heavier than bare aerogel

Verified product values

ProductPropertyValueConditionSource
Rogers ProCell TB1000 thermal insulation board
Rogers Corporation
k at ~25 °C, W/(m·K)0.029 W/(m·K)25 °C, ISO 8301, typical[4], p. 1
Rogers ProCell TB1000 thermal insulation board
Rogers Corporation
k at elevated temperature0.030 W/(m·K)200 °C, ISO 8301, typical[4], p. 1
Rogers ProCell TB1000 thermal insulation board
Rogers Corporation
k at elevated temperature0.032 W/(m·K)400 °C, ISO 8301, typical[4], p. 1
Rogers ProCell TB1000 thermal insulation board
Rogers Corporation
k at elevated temperature0.035 W/(m·K)600 °C, ISO 8301, typical[4], p. 1
Rogers ProCell TB1000 thermal insulation board
Rogers Corporation
k at elevated temperature0.037 W/(m·K)800 °C, ISO 8301, typical[4], p. 1
Rogers ProCell TB1000 thermal insulation board
Rogers Corporation
Density350–450 kg/m³as supplied[4], p. 1
Rogers ProCell TB1000 thermal insulation board
Rogers Corporation
Typical thickness0.8–5.0 mmavailable range (tolerance ±0.15–0.2 mm)[4], p. 1
Superwool EST M Paper (mica-laminated)
Morgan Advanced Materials
k at elevated temperature0.04 W/(m·K)200 °C, descending, thickness-dependent; thickness-dependent where stated[8], p. 2
Superwool EST M Paper (mica-laminated)
Morgan Advanced Materials
k at elevated temperature0.06 W/(m·K)400 °C, descending, thickness-dependent; thickness-dependent where stated[8], p. 2
Superwool EST M Paper (mica-laminated)
Morgan Advanced Materials
k at elevated temperature0.08–0.09 W/(m·K)600 °C, descending, thickness-dependent; thickness-dependent where stated[8], p. 2
Superwool EST M Paper (mica-laminated)
Morgan Advanced Materials
Electrical insulation> 2 kVwithstand voltage, 2 minutes[8], p. 2
Superwool EST M Paper (mica-laminated)
Morgan Advanced Materials
Typical thickness1–6 mmavailable range[8], p. 2
Superwool EST M Paper (mica-laminated)
Morgan Advanced Materials
k at elevated temperature< 230 / < 200 / < 140 °C (cold face)600 °C hot face, 20 min; 1 / 3 / 6 mm thickness[8], p. 2

Commercial examples

Listed for reference. Not an endorsement and not paid for.

Choosing a material for a specific cell or part?

Tell us the cell format, thickness, size and test standard, and we reply with sourced options. Submit a requirement

Sources

  1. Rubitherm Technologies GmbH. RT35HC data sheet. Datasheet, accessed 2026-11-15. Archived copy.SHA-256 d028ca73db2a3f534ea05aab8274b6b56de0cc800b7a48ce4be63fa2d00724fe
  2. VRI Composites (distributor, Augsburg, Germany). PAMITHERM 41130 product page. Datasheet, accessed 2026-11-15.
  3. 3M. 3M Thermal Runaway Barrier 600/700 Series, product page. manufacturer page, accessed 2026-11-15.
  4. Rogers Corporation. ProCell TB1000 Thermal Insulation Board, product data sheet (publication 180-506). Datasheet, accessed 2026-11-15. Archived copy.SHA-256 2a72add859e4d836100d47ae18e04c7164cb4c5e00c7ecb87cf302ea61dea302
  5. Morgan Advanced Materials (Thermal Ceramics). EST E Paper, product data sheet (publication date 1 January 2025). Datasheet, accessed 2026-11-15. Archived copy.SHA-256 5afe8b942e72a8a65ca97155826b451769acd207bf2793aec76897a11a2ea3ab
  6. Morgan Advanced Materials (Thermal Ceramics). EST G Paper, product data sheet (publication date 1 January 2025). Datasheet, accessed 2026-11-15. Archived copy.SHA-256 4ab3bd2d2e12a138e5b9c689c3ed28a6facdb7365128253cb58451404fed7c1e
  7. Morgan Advanced Materials (Thermal Ceramics). EST P Paper, product data sheet (publication date 1 January 2025). Datasheet, accessed 2026-11-15. Archived copy.SHA-256 425a76a78ea166b82388fe540bec65b014295d1ee1d5f86ea324076f1d00eb30
  8. Morgan Advanced Materials (Thermal Ceramics). EST M Paper, product data sheet (publication date 1 January 2025). Datasheet, accessed 2026-11-15.SHA-256 3dbf4ec8620abe09937ce8cf89275ea9e0848a440437bc5f28132b15b16d920d
  9. Morgan Advanced Materials (Thermal Ceramics). EST Compression Papers (C30, C310), product data sheet (publication date 1 January 2025). Datasheet, accessed 2026-11-15.SHA-256 e10ce721f30b0a050808999bd8242a6a146b06a98da07e9157853fb21de4f95c